Basic Electrical
Everyday sums. They run in the browser, and the answers are guides rather than a design certificate.
Enter any two of voltage, current, resistance or watts. Also turn voltage and current into kilowatts, kVA and kvar, single-phase or three-phase.
Open the calculatorSeries, parallel, or series strings in parallel branches. Add and remove resistors, and enter a supply voltage to split current and watts.
Open the calculatorRead the bands, including tolerance, or type a resistance and see the nearest E24 colours.
Open the calculatorPower, hours of use and your unit rate, turned into kilowatt-hours and a running cost. The sample rate is there to edit.
Open the calculatorSee how much you could save by switching to LED lighting from your current bulbs, hours and electricity rate.
Calculate my savingsCables, Faults & Machines
Closer to the work on site. Still a guide: confirm k, voltage drop and disconnection times in BS 7671 before you install.
Enter any of Zs, Ze, R1, R2, R1+R2, end-to-end readings or cable length. The rest is filled in to BS 7671 20°C copper values.
Open the calculatorCurrent, length and conductor size for copper or aluminium, single-phase or three-phase, checked against 3% or 5%.
Open the calculatorMinimum protective conductor size from fault current, disconnection time and k. Suggests the next standard cross-section.
Open the calculatorkVA and kvar from real power, plus the capacitor size and the drop in line current when you raise the power factor.
Open the calculatorTurns ratio, the missing voltage or turn count, and secondary current from primary current.
Open the calculatorDesign & Test Checks
Fault current, design current, Zs, demand and containment. Where a regulation table would normally be used, the pass line is rounded down and marked as a cautious screen.
Prospective fault current from loop impedance at the origin or at the end of the circuit.
Open the calculatorWatts or kilowatts to amps for single-phase and three-phase loads, with power factor.
Open the calculatorMaximum length or minimum conductor size for a 3% or 5% voltage-drop limit.
Open the calculatorHow long a conductor can carry a fault current before it is below the adiabatic limit.
Open the calculatorMeasured Zs against a cautious breaker limit, or against the maximum you type in from BS 7671.
Open the calculatorMaximum earth electrode resistance for an RCD, and the touch voltage at the residual current.
Open the calculatorConvert a measured resistance from one conductor temperature to another.
Open the calculatorNeutral current from three line currents, with an optional uplift for electronic loads.
Open the calculatorA rounded-down current for a conductor size. A pass is cautious. Selection still belongs in Appendix 4.
Open the calculatorLighting, sockets, cookers and fixed loads, with diversity kept mean so the demand stays high.
Open the calculatorFill from the diameters you measure. The pass line is 35%, inside the usual space factor.
Open the calculatorSuggests a CPC as large as the line conductor, and can show the adiabatic size alongside.
Open the calculatorThese calculators are quick guides for a ballpark figure. They are not certified design or test software, and a result is not a design, a certificate, or a substitute for the current edition of BS 7671. Check the working and cross-reference it before you apply it to a real installation. Thanet Electrical Ltd does not accept liability for loss or cost arising from reliance on these figures, except where the law does not allow that liability to be excluded, including death or personal injury caused by negligence.
Pricing calculators for EICR, rewires, consumer units and EV chargers live separately from these tools